Parameters |
System Rating |
1kVA |
Operating DC Voltage |
12V |
Switching Element |
Mosfet |
Charger Topology |
Boost Mosfet |
Grid Setable Range |
Nominal Grid Voltage |
230V |
Battery Low Buzzer |
10.8V |
Battery Low Cut – 0.3V |
Battery Low Cut |
10.5V |
10-11.5V |
Battery High Cut |
16.5 |
16.5-17.5V |
SPV Charging Current |
18A |
11-40A |
SPV Charging Voltage Boost |
SMF |
13.7V |
13.5-14.5V |
TUB |
15V |
14-15.5V |
SPV Charging Voltage Floot |
SMF |
13.7V |
13.5-14.5V |
TUB |
14.2V |
13.8-14.5V |
Grid-Battery Charging Voltage Boost |
SMF |
13.5V |
13.5-14.2V |
TUB |
14.5V |
13.5-15V |
Grid-Battery Charging Voltage Float |
SMF |
13.5V |
13.5-14.2V |
TUB |
13.8V |
13-14.2V |
Grid-Battery Charging Current |
10A/15A |
3A-15A |
Grid Reconnect @ Battery Voltage |
11.8V |
11-12V |
Grid Low Cut Voltage |
IT Mode Enable |
170V±10V |
IT Mode Disable |
100V±10V |
Grid Low Cut Recovery |
IT Mode Enable |
180V±10V |
IT Mode Disable |
110V±10V |
Grid High Cut Voltage |
IT Mode Enable |
265V±10V |
IT Mode Disable |
290V±10V |
Grid High Cut Recovery |
IT Mode Enable |
255V±10V |
IT Mode Disable |
280V±10V |
Change Over (Battery to Mains) |
IT Mode Enable/Disable |
<5ms |
Change Over (Mains to Battery) |
IT Mode Enable |
<10ms |
IT Mode Disable |
<60ms |
Operating Mode |
Smart/PCU/Hybrid, Default – SMT |
Inverter |
Output Phase |
1 Phase,3 Wire |
Nominal Output Voltage |
220 ±8% |
Nominal Frequency |
50 ±1% |
Load Power Factor |
0.8 |
Output Waveform |
Sinewave |
Typical Efficiency |
>80% |
Voltage Harmonic |
<3% (Liner Load) |
*Overload Capacity (IT Load Enable)% |
100-110:10 Min 150-200:2 sec
110-120:2 Min 200-300:1Sec
120-150 :30sec >350:20ms |
* Overload Capacity (IT Load Disable)% |
100-120 (3time auto reset):60 sec 250-350:1 sec 120-150 (3time auto reset) : 30 sec >350:20ms 150-200 : 2sec |
Protection |
Overload, Battery Low, Battery High, Output Short Ckt, Battery Reverse, Phase reverse, Over Heat, Over frequency, Under frequency, SPV High |
LED Indication |
System ON, (IT mode, SMF/TUB, Boost Chd, DG mode, Grid Chg.) Enable/Disable |
Switches |
Reset for System ON/OFF, UP, Down, Back, Enter (For LCD Calibration) |
Display |
Battery Voltage, Charging Current, Grid Voltage, Grid Frequency, Output Voltage, Output Frequency, Load %, Battery Graph, Overheat, SPV Current, Working Mode(HYB/PCU/SMT) |
Solar |
Switching Element |
Mosfet |
Controller |
Yes |
Type of Charger |
MPPT with PWM |
Efficiency |
>94% |
Input Voltage Range (Min – Max) Voc |
15-45V |
Maximum PV Power Recommended |
1000W |
Environment |
Operating Temperature |
0-50°C |
Cooling |
Fan |
Max. Relative Humidity @ 25*C (Non Condensing) |
95% |
Noise @ 1meter |
50dB |
Standard Compliance |
|
Dimension (LXWXH)mm |
305.5 x 327.8 x 116 |